易驱 EASYDRIVE ED3100 系列故障代码表(19 条) · ED3100
本页收录 易驱 EASYDRIVE ED3100 系列(ED3100)的 19 条故障代码,含每条码的故障名称、可能原因与处理对策。数据取自厂商官方手册,可对照原件复查。
💡 发现错漏?某个码缺失、含义不对,或您手上有该型号的官方手册 —— 欢迎发邮件到 417887649@qq.com,核验后我们会更正,并把来源标注升级为「官方手册」。
📚 数据来源 本页 19 条码取自厂商官方手册,已逐条核对;具体手册名称与版本见本页末尾「数据来源说明」。
| 故障代码 | 故障名称 | 可能原因 | 处理对策 |
|---|---|---|---|
| Er00 | [提示] 加速运行中过流 | ①Too short accelerating time ②Ultra large load inertia. ③ Unsuitable V/F curve ④Ultra low main voltage ⑤Too small inverter power ⑥Restart the rotating motor | ①Extend accelerating time ②Reduce the load inertia ③Reduce torque boost value or adjust V/F curve ④Examine input power supply ⑤Choose the inverter of large power ⑥Set the speed-detection start function |
| Er01 | [提示] 减速运行中过流 | ①Too short decelerating time ②Ultra large load inertia. ③Too small inverter power | ①Extend decelerating time ②Reduce the load inertia ③Choose the inverter of large power |
| Er02 | [提示] 恒速运行中过流 | ①Abnormal input voltage ②Load occurs abrupt change or abnormity ③ Too small inverter power | ①Examine input power ②Examine load or reduce the abrupt change of load ③Choose the inverter of large power |
| Er03 | [提示] 加速运行中过压 | ①Abnormal input voltage ②Restart the rotating motor | ①Examine input power ②Set the speed-detection start function |
| Er04 | [提示] 减速运行中过压 | ①Too short decelerating time ②There is energy feedback load ③Abnormal input power supply | ①Extend decelerating time ②Add braking power of external energy consumption braking unit ③Examine input power |
| Er05 | [提示] 恒速运行中过压 | ①Abnormal input voltage ②Ultra large load inertia. | ① Examine input power ②Choose energy consumption braking unit |
| Er06 | [严重] 停机时过压 | ①Abnormal input supply voltage | ①Examine input supply voltage |
| Er07 | [提示] 运行中欠压 | ① Abnormal input voltage | ①Examine supply voltage |
| Er08 | [警告] 输入电源缺相 | ①Input power occurs phase failure or abnormity | ① Examine input power supply |
| Er09 | [警告] 模块故障 | ① Inverter outputs short circuit or earthing. ② Instant over current of inverter ③Too high environment temperature ④Air flue is blocked or fan is damaged ⑤DC auxiliary power supply occurs fault ⑥ Abnormal controlpanel | ① Examine the connecting wire; ② Refer to solution against over current ③ Reduce environment temperature ④ Clean the air flue or change the fan; ⑤ Ask for service from manufacturer or agency. ⑥ Ask for service from manufacturer or agency. |
| Er10 | [警告] 散热器过热 | ① Too high environment temperature ② Fan is damaged ③ Flue is blocked | ① Lower environment temperature ② Change the fan ③ Clean the flue and change the ventilation condition |
| Er11 | [警告] 变频器过载 | ① Too high torque boost or unsuitable V/F curve ② Too short accelerating time ③ Too large load | ①Reduce the torque boost and adjust the V/F curve. ② Extend accelerating time ③Reduce load or choose the inverter of large power |
| Er12 | [警告] 电机过载 | ①Too high torque boost or unsuitable V/F curve ② Too low main voltage ③Locked rotor of motor or too large abrupt change of load ④Incorrect setting of motor overload protection factor | ① Reduce the torque boost value or adjust the V/F curve. ② Examine main voltage ③ Examine load ④Set the motor overload protection factor correctly |
| Er13 | [提示] 外部设备故障 | ①Fault input terminal of peripheral equipment is close | ①Disconnect the terminal input and remove the fault. |
| Er14 | [提示] 串口通讯故障 | ① Improper setting of baud rate ② False of serial port communication ③ Without upper machine communication signal | ① Set baud rate correctly ②Examine communication cable and ask for service ③Check whether PC works and the connection is correct. |
| Er15 | [警告] 保留 | — | — |
| Er16 | [严重] 电流检测异常 | ① The current detecting device is damaged or the circuit occurs fault ②DC auxiliary power is damaged | ①Ask for service from manufacturer or agency. ②Ask for service from manufacturer or agency. |
| Er17 | [提示] 键盘与控制板通讯故障 | ①The circuit connecting keyboard and control panel occurs fault ② The terminal is poor in connecting | ① Ask for service ② Examine and reconnect |
| Er18 | [严重] CPU 故障 | — | — |
数据来源说明:
✅ 数据来源等级:official(官方手册原件直取)—— 2026-10-20 新增
本表 19 条(Er00 ~ Er18)取自 《ED3100 series and MINI series high performance general purpose inverter instruction manual》(英文版,全 126 页)第 7 章 7.1「Failure and countermeasure」表 7-1。
手册原文明确写:「the fault code display range is Er00-Er18」——即本系列故障码就是 Er00 到 Er18 共 19 个。
📌 与「易驱 ED3000S / ED2003 / ED2800」是不同系列:
· 本条:ED3100 系列(官方手册直取,19 条)
· 另一条:ED3000S / ED2003 / ED2800(二手资料,32 条,尚未获官方原件)
两个条目的码表不通用,请按设备铭牌上的实际型号对照。
📌 原因与对策是英文原文:手册只有英文版,我们没有机翻——故障名称已由英文直译(例:Er00 Over current at accelerating operation → 加速运行中过流),原因/对策保留英文原文,附在每条里。
如需中文版,欢迎通过页面底部邮箱提供该系列中文手册。
📌 两处手册自身的问题,如实标注未改:
· Er15 手册写「Reserved」→ 名称「保留」,没有编造原因对策
· Er18 手册写「CUP fault」→ 应为 CPU,名称按语义写「CPU 故障」并注明原文
📌 手册文件:1,289,517 字节 / 126 页 / 有效 PDF。
数据经乱码闸门检查(无 U+FFFD、无连续问号、无乱码特征)。
🔍 2026-10-26 新发现:本表与「康沃 CVF-G3/P2」是同一套故障表
做全库交叉比对时发现,本条目与 康沃 Concord CONVO CVF-G3/P2 的 故障码高度一致,只是起始编号差一位:
· 易驱:`Er00` = 加速运行中过流
· 康沃:`ER01` = 加速中过流(康沃没有 ER00,所以整体后移一位)
推断:国内变频器行业常见的共用参考设计/贴牌情况。
📌 这不是数据串号 —— 我们逐码核对过英文/中文语义,能一一对应。
📌 数据本身仍以本手册(ED3100 英文版第 7 章表 7-1)为准,没有拿康沃的数据来凑。
🧹 已清理源站广告残留:本条目的部分原因/对策原抓取自二手维修站,其中混入了该站的「城市+变频器维修」堆砌页脚与网址,已自动删除,只保留真实故障内容。
✅ 数据来源等级:official(官方手册原件直取)—— 2026-10-20 新增
本表 19 条(Er00 ~ Er18)取自 《ED3100 series and MINI series high performance general purpose inverter instruction manual》(英文版,全 126 页)第 7 章 7.1「Failure and countermeasure」表 7-1。
手册原文明确写:「the fault code display range is Er00-Er18」——即本系列故障码就是 Er00 到 Er18 共 19 个。
📌 与「易驱 ED3000S / ED2003 / ED2800」是不同系列:
· 本条:ED3100 系列(官方手册直取,19 条)
· 另一条:ED3000S / ED2003 / ED2800(二手资料,32 条,尚未获官方原件)
两个条目的码表不通用,请按设备铭牌上的实际型号对照。
📌 原因与对策是英文原文:手册只有英文版,我们没有机翻——故障名称已由英文直译(例:Er00 Over current at accelerating operation → 加速运行中过流),原因/对策保留英文原文,附在每条里。
如需中文版,欢迎通过页面底部邮箱提供该系列中文手册。
📌 两处手册自身的问题,如实标注未改:
· Er15 手册写「Reserved」→ 名称「保留」,没有编造原因对策
· Er18 手册写「CUP fault」→ 应为 CPU,名称按语义写「CPU 故障」并注明原文
📌 手册文件:1,289,517 字节 / 126 页 / 有效 PDF。
数据经乱码闸门检查(无 U+FFFD、无连续问号、无乱码特征)。
🔍 2026-10-26 新发现:本表与「康沃 CVF-G3/P2」是同一套故障表
做全库交叉比对时发现,本条目与 康沃 Concord CONVO CVF-G3/P2 的 故障码高度一致,只是起始编号差一位:
· 易驱:`Er00` = 加速运行中过流
· 康沃:`ER01` = 加速中过流(康沃没有 ER00,所以整体后移一位)
推断:国内变频器行业常见的共用参考设计/贴牌情况。
📌 这不是数据串号 —— 我们逐码核对过英文/中文语义,能一一对应。
📌 数据本身仍以本手册(ED3100 英文版第 7 章表 7-1)为准,没有拿康沃的数据来凑。
🧹 已清理源站广告残留:本条目的部分原因/对策原抓取自二手维修站,其中混入了该站的「城市+变频器维修」堆砌页脚与网址,已自动删除,只保留真实故障内容。
其他品牌故障代码:
优利康 YOULIKANG YD5000 系列正阳 ZHENGYANG ZY-812众辰 Zhongchen易驱 EASYDRIVE ED3000S / ED2003 / ED2800 / D3100 系列浙江易控 EACN EC6000 系列亚泰 YATAI YTD-G
优利康 YOULIKANG YD5000 系列正阳 ZHENGYANG ZY-812众辰 Zhongchen易驱 EASYDRIVE ED3000S / ED2003 / ED2800 / D3100 系列浙江易控 EACN EC6000 系列亚泰 YATAI YTD-G
🔗 本品牌故障码的跨品牌对照页
点码名可看「还有哪些品牌也有这个码」——同类码在不同品牌的含义对照。
Er00 Er01 Er02 Er03 Er04 Er05 Er06 Er07 Er08 Er09 Er10 Er11 Er12 Er13 Er14 Er15 Er16 Er17 Er18
点码名可看「还有哪些品牌也有这个码」——同类码在不同品牌的含义对照。
Er00 Er01 Er02 Er03 Er04 Er05 Er06 Er07 Er08 Er09 Er10 Er11 Er12 Er13 Er14 Er15 Er16 Er17 Er18
⚠️ 免责声明
本页数据取自厂商官方手册/说明书原件,可对照原件复查。 现场使用前请以设备自带手册为准。
本页内容仅供参考,因使用本页信息造成的任何后果由使用者自行承担。
📮 帮我们补全
如果本页有错漏 —— 比如某个码缺失、含义不对、或者您手上有该型号的官方手册,欢迎发邮件到 417887649@qq.com(附上品牌型号与手册照片/PDF 更好)。核验后我们会更新数据,并把来源标注从「二手资料」升级为「官方手册」。
本页数据取自厂商官方手册/说明书原件,可对照原件复查。 现场使用前请以设备自带手册为准。
本页内容仅供参考,因使用本页信息造成的任何后果由使用者自行承担。
📮 帮我们补全
如果本页有错漏 —— 比如某个码缺失、含义不对、或者您手上有该型号的官方手册,欢迎发邮件到 417887649@qq.com(附上品牌型号与手册照片/PDF 更好)。核验后我们会更新数据,并把来源标注从「二手资料」升级为「官方手册」。